Non-Contact Safety Switches in Context
Application Gallery
Product Options
Non-Contact Safety Switches Products
Safety Relay Required
| Image | Product | Safety Standard / Category | Safety Outputs | Aux Output | Switching Distance | Hysteresis | Connection / Housing / Notes | Operating Temp | IP Rating | Datasheet | |
|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
ANATOM 78S | Coded magnetic safety switch | EN ISO 13849-1 PLe / Cat.4 | 2 NO, 0.8 A max 24 V | 1 NC PNP 250 mA | 10 mm | 2 mm | Cable (3 m / 6 m / 12 m) or 50 cm M12; Polyamide6 housing; double brackets | –25 °C to +60 °C | IP67 | View Datasheet |
![]() |
ANATOM 98S | Coded magnetic safety switch | EN ISO 13849-1 PLe / Cat.4 | 2 NO, 0.8 A max 24 V | 1 NO PNP 250 mA | 10 mm | 2 mm | Cable (3 m / 6 m / 12 m) or 50 cm M12; Polyamide6 housing; double brackets | –25 °C to +60 °C | IP67 | View Datasheet |
![]() |
OPTOPUS | Coded magnetic safety switch (miniature) | EN ISO 13849-1 PLe / Cat.4 | 2 NO, 0.4 A max 24 V | 1 NC PNP 250 mA | 9 mm | 1 mm | Cable options; Polyamide6 housing; double brackets; series-mountable up to 30 | –20 °C to +60 °C | IP67 | View Datasheet |
![]() |
XORF-S | Coded RFID safety switch | EN ISO 13849-1 PLe / Cat.4 | 2 NO, 50 mA / 30 V | 1 PNP 50 mA | 20 mm | Cable options; Polyamide6 housing; double brackets; 16M code combinations | –30 °C to +50 °C | IP67 | View Datasheet | |
![]() |
ANATOM M18 | Coded magnetic safety switch (cylindrical) | EN ISO 13849-1 PLe / Cat.4 | 2 NO, 0.8 A max 24 V | 1 NC PNP 250 mA | 6 mm | 2 mm | M12 8-pin; CuNi M18 housing | –20 °C to +60 °C | IP67 | View Datasheet |
![]() |
MASSIMOTTO 78S | Coded magnetic safety switch | EN ISO 13849-1 PLe / Cat.4 | 2 NO 2 A / 48 V | 2 NC PNP 250 mA | 10 mm | 2 mm | Dual M12 connectors; Polyamide6 housing; 4×M4 fixings | –25 °C to +60 °C | View Datasheet | |
![]() |
MASSIMOTTO 98S | Coded magnetic safety switch | EN ISO 13849-1 PLe / Cat.4 | 2 NO, 0.8 A max 24 V | 1 NO PNP 250 mA | 10 mm | 2 mm | Dual M12 connectors; Polyamide6 housing; 4×M4 fixings | –25 °C to +60 °C | IP67 | View Datasheet |
![]() |
ANATOM 78S INOX | Coded magnetic — stainless steel | EN ISO 13849-1 PLe / Cat.4 | 2 NO 250 mA / 48 V | 1 NC PNP 250 mA | 10 mm | 2 mm | Cable/M12; 316L stainless steel housing | –20 °C to +60 °C | IP69K | View Datasheet |
![]() |
ANATOM 98S INOX | Coded magnetic — stainless steel | EN ISO 13849-1 PLe / Cat.4 | 2 NO, 0.8 A max 24 V | 1 NO PNP 250 mA | 10 mm | 2 mm | Cable/M12; 316L stainless steel housing | –25 °C to +60 °C | IP69K | View Datasheet |
![]() |
OPTOPUS INOX | Coded magnetic — miniature, stainless steel | EN ISO 13849-1 PLe / Cat.4 | 2 NO, 0.4 A max 24 V | 1 NC PNP 250 mA | 9 mm | 1 mm | Cable/M12; 316L stainless steel; series-mountable | –20 °C to +60 °C | IP69K | View Datasheet |
![]() |
TRITHON INOX | Coded magnetic — stainless steel | EN ISO 13849-1 PLe / Cat.4 | 2 NO, 1 A max 24 V | 1 NC PNP 1 A | 9 mm | 2 mm | 50 cm cable + M12; 316L stainless steel; laser-etched | –30 °C to +110 °C | IP69K | View Datasheet |
No Safety Relay Required
| Image | Product | Safety Standard / Category | Safety Outputs | Aux Output | Switching Distance | Hysteresis | Connection / Housing / Notes | Operating Temp | IP Rating | Datasheet | |
|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
AMX3 | Coded magnetic — standalone | EN ISO 13849-1 PLd (PLe w/ relay) | 1 NO 2 A / 48 V | 1 NC PNP 250 mA | 10 mm | 2 mm | Cable/M12; Polyamide6 housing | –25 °C to +60 °C | IP67 | View Datasheet |
![]() |
AMX4 | Coded magnetic — standalone | EN ISO 13849-1 PLd (PLe w/ relay) | 2 NO 2 A / 48 V | 10 mm | 2 mm | Cable/M12; Polyamide6 | –25 °C to +60 °C | IP67 | View Datasheet | |
![]() |
AMX5 | Coded magnetic — standalone | EN ISO 13849-1 PLd (PLe w/ relay) | 2 NO 2 A / 48 V | 1 NC PNP 250 mA | 10 mm | 2 mm | Cable/M12; Polyamide6 | –25 °C to +60 °C | IP67 | View Datasheet |
![]() |
AMXR-S | Coded RFID — standalone | EN ISO 13849-1 PLd (PLe w/ relay) | 2 NO 2 A / 48 V | 1 NC PNP 400 mA | 24 mm | Cable/M12; Polyamide6; 16M code options | Cable/M12; Polyamide6; 16M code options | IP67 | View Datasheet | |
![]() |
VIGIL RS | Coded magnetic — standalone | EN ISO 13849-1 PLd (PLe w/ relay) | 2 NO 2 A / 48 V | 1 NC PNP 250 mA | 10 mm | 2 mm | Cable/M12; Polyamide6; built-in reset | –20 °C to +60 °C | IP67 | View Datasheet |
![]() |
AMX5CK | Coded magnetic — standalone | EN ISO 13849-1 PLd (PLe w/ relay) | 2 NO 2 A / 48 V | 2 NC PNP 250 mA | 10 mm | 2 mm | M12 8-pin; Polyamide6; personnel key included | –25 °C to +60 °C | IP67 | View Datasheet |
![]() |
MASSIMOTTO (standalone) | Coded magnetic — standalone | EN ISO 13849-1 PLd (PLe w/ relay) | 2 NO 2 A / 48 V | 1 NC PNP 250 mA | 8 mm | 3 mm | Dual M12 connectors; Polyamide6; 4×M4 fixings | –25 °C to +60 °C | IP67 | View Datasheet |
![]() |
OPTO2S | Coded magnetic — standalone (miniature) | EN ISO 13849-1 PLc (PLe w/ relay) | 2 NO 250 mA / 48 V | 7 mm | 2 mm | Cable; Polyamide6; miniature housing | –20 °C to +60 °C | IP67 | View Datasheet | |
![]() |
7SSR24V | Coded magnetic — standalone, cylindrical | EN ISO 13849-1 PLc (PLe w/ relay) | 2 NO 1 A / 48 V | 1 NC PNP 1 A | 6 mm | 2 mm | Cable; CuNi M30 cylindrical housing | –25 °C to +60 °C | IP67 | View Datasheet |
![]() |
AMX3 INOX | Coded magnetic — stainless steel | EN ISO 13849-1 PLd (PLe w/ relay) | 1 NO 2 A / 48 V | 1 NC PNP 250 mA | 10 mm | 2 mm | Cable/M12; 316L stainless steel | –25 °C to +60 °C | IP69K | View Datasheet |
![]() |
AMX5 INOX | Coded magnetic — stainless steel | EN ISO 13849-1 PLd (PLe w/ relay) | 2 NO 2 A / 48 V | 1 NC PNP 250 mA | 10 mm | 2 mm | Cable/M12; 316L stainless steel | –25 °C to +60 °C | IP69K | View Datasheet |
ATEX Rated
| Image | Product | Safety Standard / Category | Safety Outputs | Aux Output | Switching Distance | Hysteresis | Connection / Housing / Notes | Operating Temp | IP Rating | Datasheet | |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
RDX8 | ATEX non-contact safety switch | ATEX Zone 2/22 | 2 NO 50 mA / 24 V | 1 NC PNP 50 mA | 17 mm | 5 mm | Cable; Polyamide6; series-mountable up to 30 | –5 °C to +80 °C | IP67 | View Datasheet |
|
ANATOM 78S PL EEX | ATEX Zone 0/20 | 2 NO 50 mA / 12 V | 1 NC PNP 15 mA / 12 V | 10 mm | 4 mm | 12 m cable; Polyamide6 | –20 °C to +40 °C | IP67 | View Datasheet | |
|
ANATOM 78S INOX EEX | ATEX Zone 1/21 | 2 NO 50 mA / 12 V | 1 NC PNP 15 mA / 12 V | 10 mm | 4 mm | 12 m cable; 316L stainless steel | –20 °C to +40 °C | IP69K | View Datasheet |
Unsure what you need?
If you’re unsure whether or not your machinery complies with current safety regulations, speak to our machinery safety experts today, we’re always happy to help.