Safety Switches and Devices

Non-Contact Safety Switches

Safety Switches For Any Application.

Non-contact switches are safety interlocking devices designed to prevent the need for mechanically linked interlocks where physical parts touch. They also help with the prevention of interlocks being defeated, have tolerance for misalignment, wear less over time, and support higher safety ratings i.e SIL or PLr.

  • 1. Hinged doors or gates
  • 2. Sliding doors or gates
  • 3. Machines with a high frequency of access gates
  • 4. Mechanical guarding access points
  • 1. Easy to install
  • 2. Straightforward wiring connections
  • 3. Aren’t affected by small build ups of dirt or dust
  • 4. Can sense through up to 6mm of stainless steel
Non-Contact Safety Switches in Context

Application Gallery

Product Options

Non-Contact Safety Switches Products

Safety Relay Required
Image Product Safety Standard / Category Safety Outputs Aux Output Switching Distance Hysteresis Connection / Housing / Notes Operating Temp IP Rating Datasheet
ANATOM 78S Coded magnetic safety switch EN ISO 13849-1 PLe / Cat.4 2 NO, 0.8 A max 24 V 1 NC PNP 250 mA 10 mm 2 mm Cable (3 m / 6 m / 12 m) or 50 cm M12; Polyamide6 housing; double brackets –25 °C to +60 °C IP67 View Datasheet
ANATOM 98S Coded magnetic safety switch EN ISO 13849-1 PLe / Cat.4 2 NO, 0.8 A max 24 V 1 NO PNP 250 mA 10 mm 2 mm Cable (3 m / 6 m / 12 m) or 50 cm M12; Polyamide6 housing; double brackets –25 °C to +60 °C IP67 View Datasheet
OPTOPUS Coded magnetic safety switch (miniature) EN ISO 13849-1 PLe / Cat.4 2 NO, 0.4 A max 24 V 1 NC PNP 250 mA 9 mm 1 mm Cable options; Polyamide6 housing; double brackets; series-mountable up to 30 –20 °C to +60 °C IP67 View Datasheet
XORF-S Coded RFID safety switch EN ISO 13849-1 PLe / Cat.4 2 NO, 50 mA / 30 V 1 PNP 50 mA 20 mm Cable options; Polyamide6 housing; double brackets; 16M code combinations –30 °C to +50 °C IP67 View Datasheet
ANATOM M18 Coded magnetic safety switch (cylindrical) EN ISO 13849-1 PLe / Cat.4 2 NO, 0.8 A max 24 V 1 NC PNP 250 mA 6 mm 2 mm M12 8-pin; CuNi M18 housing –20 °C to +60 °C IP67 View Datasheet
MASSIMOTTO 78S Coded magnetic safety switch EN ISO 13849-1 PLe / Cat.4 2 NO 2 A / 48 V 2 NC PNP 250 mA 10 mm 2 mm Dual M12 connectors; Polyamide6 housing; 4×M4 fixings –25 °C to +60 °C View Datasheet
MASSIMOTTO 98S Coded magnetic safety switch EN ISO 13849-1 PLe / Cat.4 2 NO, 0.8 A max 24 V 1 NO PNP 250 mA 10 mm 2 mm Dual M12 connectors; Polyamide6 housing; 4×M4 fixings –25 °C to +60 °C IP67 View Datasheet
ANATOM 78S INOX Coded magnetic — stainless steel EN ISO 13849-1 PLe / Cat.4 2 NO 250 mA / 48 V 1 NC PNP 250 mA 10 mm 2 mm Cable/M12; 316L stainless steel housing –20 °C to +60 °C IP69K View Datasheet
ANATOM 98S INOX Coded magnetic — stainless steel EN ISO 13849-1 PLe / Cat.4 2 NO, 0.8 A max 24 V 1 NO PNP 250 mA 10 mm 2 mm Cable/M12; 316L stainless steel housing –25 °C to +60 °C IP69K View Datasheet
OPTOPUS INOX Coded magnetic — miniature, stainless steel EN ISO 13849-1 PLe / Cat.4 2 NO, 0.4 A max 24 V 1 NC PNP 250 mA 9 mm 1 mm Cable/M12; 316L stainless steel; series-mountable –20 °C to +60 °C IP69K View Datasheet
TRITHON INOX Coded magnetic — stainless steel EN ISO 13849-1 PLe / Cat.4 2 NO, 1 A max 24 V 1 NC PNP 1 A 9 mm 2 mm 50 cm cable + M12; 316L stainless steel; laser-etched –30 °C to +110 °C IP69K View Datasheet
No Safety Relay Required
Image Product Safety Standard / Category Safety Outputs Aux Output Switching Distance Hysteresis Connection / Housing / Notes Operating Temp IP Rating Datasheet
AMX3 Coded magnetic — standalone EN ISO 13849-1 PLd (PLe w/ relay) 1 NO 2 A / 48 V 1 NC PNP 250 mA 10 mm 2 mm Cable/M12; Polyamide6 housing –25 °C to +60 °C IP67 View Datasheet
AMX4 Coded magnetic — standalone EN ISO 13849-1 PLd (PLe w/ relay) 2 NO 2 A / 48 V 10 mm 2 mm Cable/M12; Polyamide6 –25 °C to +60 °C IP67 View Datasheet
AMX5 Coded magnetic — standalone EN ISO 13849-1 PLd (PLe w/ relay) 2 NO 2 A / 48 V 1 NC PNP 250 mA 10 mm 2 mm Cable/M12; Polyamide6 –25 °C to +60 °C IP67 View Datasheet
AMXR-S Coded RFID — standalone EN ISO 13849-1 PLd (PLe w/ relay) 2 NO 2 A / 48 V 1 NC PNP 400 mA 24 mm Cable/M12; Polyamide6; 16M code options Cable/M12; Polyamide6; 16M code options IP67 View Datasheet
VIGIL RS Coded magnetic — standalone EN ISO 13849-1 PLd (PLe w/ relay) 2 NO 2 A / 48 V 1 NC PNP 250 mA 10 mm 2 mm Cable/M12; Polyamide6; built-in reset –20 °C to +60 °C IP67 View Datasheet
AMX5CK Coded magnetic — standalone EN ISO 13849-1 PLd (PLe w/ relay) 2 NO 2 A / 48 V 2 NC PNP 250 mA 10 mm 2 mm M12 8-pin; Polyamide6; personnel key included –25 °C to +60 °C IP67 View Datasheet
MASSIMOTTO (standalone) Coded magnetic — standalone EN ISO 13849-1 PLd (PLe w/ relay) 2 NO 2 A / 48 V 1 NC PNP 250 mA 8 mm 3 mm Dual M12 connectors; Polyamide6; 4×M4 fixings –25 °C to +60 °C IP67 View Datasheet
OPTO2S Coded magnetic — standalone (miniature) EN ISO 13849-1 PLc (PLe w/ relay) 2 NO 250 mA / 48 V 7 mm 2 mm Cable; Polyamide6; miniature housing –20 °C to +60 °C IP67 View Datasheet
7SSR24V Coded magnetic — standalone, cylindrical EN ISO 13849-1 PLc (PLe w/ relay) 2 NO 1 A / 48 V 1 NC PNP 1 A 6 mm 2 mm Cable; CuNi M30 cylindrical housing –25 °C to +60 °C IP67 View Datasheet
AMX3 INOX Coded magnetic — stainless steel EN ISO 13849-1 PLd (PLe w/ relay) 1 NO 2 A / 48 V 1 NC PNP 250 mA 10 mm 2 mm Cable/M12; 316L stainless steel –25 °C to +60 °C IP69K View Datasheet
AMX5 INOX Coded magnetic — stainless steel EN ISO 13849-1 PLd (PLe w/ relay) 2 NO 2 A / 48 V 1 NC PNP 250 mA 10 mm 2 mm Cable/M12; 316L stainless steel –25 °C to +60 °C IP69K View Datasheet
ATEX Rated
Image Product Safety Standard / Category Safety Outputs Aux Output Switching Distance Hysteresis Connection / Housing / Notes Operating Temp IP Rating Datasheet
RDX8 ATEX non-contact safety switch ATEX Zone 2/22 2 NO 50 mA / 24 V 1 NC PNP 50 mA 17 mm 5 mm Cable; Polyamide6; series-mountable up to 30 –5 °C to +80 °C IP67 View Datasheet
ANATOM 78S PL EEX ATEX Zone 0/20 2 NO 50 mA / 12 V 1 NC PNP 15 mA / 12 V 10 mm 4 mm 12 m cable; Polyamide6 –20 °C to +40 °C IP67 View Datasheet
ANATOM 78S INOX EEX ATEX Zone 1/21 2 NO 50 mA / 12 V 1 NC PNP 15 mA / 12 V 10 mm 4 mm 12 m cable; 316L stainless steel –20 °C to +40 °C IP69K View Datasheet

Unsure what you need?

If you’re unsure whether or not your machinery complies with current safety regulations,
speak to our machinery safety experts today, we’re always happy to help.

ISS Safety
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.